Titanio

 
Codice 
Tensione di alimentazione 
Corrente di uscita 
Modalità di controllo Interfaccia 
Open o Close loop 
[Vcc] 
[Vac] 
[A/ph rms] 
[A/ph peak] 
Min 
Max 
Min 
Max 
Min 
Max 
Min 
Max 
SN4D2040H2L1-00c06901248  0,04,00,05,65EtherCAT (CoE)Open loop o Closed loop
SW4D2042H241-00c06901248  0,04,20,06,00EtherCAT (CoE)Open loop o Closed loop
SW4D2042E241-00c08901248  0,04,20,06,00Ethernet Modbus TCP/IPOpen loop o Closed loop
SW4D2070C231-00c03901248  0,07,00,010,0CANBus CANopenOpen loop o Closed loop
SW4D2070M231-00c04901248  0,07,00,010,0Seriale RS485 Modbus RTUOpen loop o Closed loop
SW4D2070T241-00c09901248  0,07,00,010,0ProfinetOpen loop o Closed loop
SW4D2070T241-02c09901248  0,07,00,010,0ProfinetClosed loop con encoder assoluto multigiro
SW4D2070T4S2-00c09901248  0,07,00,010,0ProfinetOpen loop o Closed loop
SW4A3070C261-00c0390  18560,07,10,010,0CANBus CANopenOpen loop o Closed loop
SW4A3070C261-01c0390  18560,07,10,010,0CANBus CANopenOpen loop o Closed loop
SW4A3070C261-02c0390  18560,07,10,010,0CANBus CANopenClosed loop con encoder assoluto multigiro
SW4A3070M261-00c0490  18560,07,10,010,0Seriale RS485 Modbus RTUOpen loop o Closed loop
SW4A3070M261-01c0490  18560,07,10,010,0Seriale RS485 Modbus RTUOpen loop o Closed loop
SW4A3070M261-02c0490  18560,07,10,010,0Seriale RS485 Modbus RTUClosed loop con encoder assoluto multigiro
SW4A3070H241-00c0690  18560,07,10,010,0EtherCAT (CoE)Open loop o Closed loop
SW4A3070H241-02c0690  18560,07,10,010,0EtherCAT (CoE)Closed loop con encoder assoluto multigiro
SW4A3070E241-00c0890  18560,07,10,010,0Ethernet Modbus TCP/IPOpen loop o Closed loop
SW4A3070E241-02c0890  18560,07,10,010,0Ethernet Modbus TCP/IPClosed loop con encoder assoluto multigiro
SW4A4085C261-00c0390  181000,08,50,012,0CANBus CANopenOpen loop
SW4A4085M261-00c0490  181000,08,50,012,0Seriale RS485 Modbus RTUOpen loop
SW5D3070R4T2-30c0A902480  0,07,10,010,0PowerLinkOpen loop o Closed loop con encoder incrementale
SW5D3070R4T2-35c0A902480  0,07,10,010,0PowerLinkOpen loop o Closed loop con encoder assoluto multigiro
SW5A4085C2N1-00c0390  181000,08,50,012,0CANBus CANopenOpen loop o Closed loop
SW5A4085C2G1-00c0390  181000,08,50,012,0CANBus CANopenOpen loop o Closed loop
SW5A4085M2N1-00c0490  181000,08,50,012,0Seriale RS485 Modbus RTUOpen loop o Closed loop
SW5A4085M2G1-00c0490  181000,08,50,012,0Seriale RS485 Modbus RTUOpen loop o Closed loop
SW5A4085E241-00c0890  181000,08,50,012,0Ethernet Modbus TCP/IPOpen loop o Closed loop
SW5A4085E2J1-00c0890  181000,08,50,012,0Ethernet Modbus TCP/IPOpen loop o Closed loop
SW5A4085H241-00c0690  181000,08,50,012,0EtherCAT (CoE)Open loop o Closed loop
SW5A4085T2N1-00c0990  181000,08,50,012,0ProfinetOpen loop o Closed loop
SW5A5080N221-30c0790-S0200  851200,08,00,011,35Clock & DirezioneOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080N221-30c0790-S0301  851200,08,00,011,35Clock & DirezioneOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080N2E1-30c0790-S0302  851200,08,00,011,35Clock & DirezioneOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080L221-30c0790  851200,08,00,011,35CANBus CANopen + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080L2E1-30c0790  851200,08,00,011,35CANBus CANopen + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080L2G1-30c0790  851200,08,00,011,35CANBus CANopen + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080E221-30c0890  851200,08,00,011,35Ethernet Modbus TCP/IPOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080E2G1-30c0890  851200,08,00,011,35Ethernet Modbus TCP/IPOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080H221-30c0690  851200,08,00,011,35EtherCAT (CoE)Open loop o Closed loop con encoder assoluto oppure incrementale
SW5A5080T221-30c0990  851200,08,00,011,35ProfinetOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9030L221-20c0790  1002400,03,000,04,20CANBus CANopen + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9030L2G1-20c0790  1002400,03,000,04,20CANBus CANopen + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9030E2G1-20c0890  1002400,03,000,04,20Ethernet Modbus TCP/IPOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9030H221-20c0690  1002400,03,000,04,20EtherCAT (CoE)Open loop o Closed loop con encoder assoluto oppure incrementale
SW5A9030T221-20c0990  1002400,03,000,04,20ProfinetOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052N221-30c0790-S0200  852650,05,20,07,35Clock & DirezioneOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052N221-30c0790-S0301  852650,05,20,07,35Clock & DirezioneOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052N2E1-30c0790-S0302  852650,05,20,07,35Clock & DirezioneOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052L221-30c0790  852650,05,20,07,35CANBus CANopen + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052L2E1-30c0790  852650,05,20,07,35CANBus CANopen + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052L2G1-30c0790  852650,05,20,07,35CANBus CANopen + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052E221-30c0890  852650,05,20,07,35Ethernet Modbus TCP/IPOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052E2G1-30c0890  852650,05,20,07,35Ethernet Modbus TCP/IPOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052H221-30c0690  852650,05,20,07,35EtherCAT (CoE)Open loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052T221-30c0990  852650,05,20,07,35ProfinetOpen loop o Closed loop con encoder assoluto oppure incrementale

Ricerca

Tensione di alimentazione
Tecnologie

Profinet nasce come il successore di Profibus ed è basato su tecnologia ethernet, con gli obiettivi di aumentare le prestazioni e semplificare l’integrazione tra dispositivi basati su hardware ethernet ed il mondo Siemens.

Il Modbus è un protocollo di comunicazione tra i più diffusi ed utilizzati nel mondo dei dispositivi industriali. Tutti i nostri dispositivi dotati di interfaccia seriale (RS232 o RS485) implementano e supportano il protocollo Modbus RTU.

Il bus di campo Modbus TCP/IP, basato su hardware Ethernet, nasce come evoluzione del classico Modbus RTU. Il protocollo di comunicazione Modbus TCP/IP basato su Ethernet consente a più master di collegarsi allo stesso slave.

Ever Elettronica è stata una tra le prime aziende al mondo ad implementare e validare il protocollo CANopen e la DSP402 sui propri azionamenti per motori passo passo e motori brushless, a partire dai primi anni ‘90.

CANopen è un protocollo standard di comunicazione largamente utilizzato nel settore industriale e dell’automazione. Ideato inizialmente per utilizzo con bus di campo CAN, è stato applicato anche ad altre tipologie di bus di campo come Ethercat CoE.

Gli azionamenti programmabili di Ever Elettronica - una novità nel mercato dell’automazione - integrano un vero e proprio PLC a bordo dell’azionamento per realizzare automazioni complesse con un unico dispositivo.

Grazie alla tecnologia ELSE integrata nella serie di azionamenti Ever Elettronica, la risoluzione della corrente di controllo del motore è talmente elevata da far sparire le vibrazioni, le risonanze ed i rumori tipici di questi motori.