Titanio

 
Codice 
Tensione di alimentazione 
Corrente di uscita 
Modalità di controllo Interfaccia 
Open o Close loop 
[Vcc] 
[Vac] 
[A/ph rms] 
[A/ph peak] 
Min 
Max 
Min 
Max 
Min 
Max 
Min 
Max 
SW3D2042H241-01c06801248  0,04,20,06,0EtherCAT CoE (DS402)Open loop
SN4D2040H2L1-00c06801248  0,04,00,05,65EtherCAT CoE (DS402)Open loop o Closed loop
SW4D2042H241-00c06801248  0,04,20,06,00EtherCAT CoE (DS402)Open loop o Closed loop
SW4D2042E241-00c08001248  0,04,20,06,00Ethernet Modbus TCP/IPOpen loop o Closed loop
SW4D2070C231-00c03801248  0,07,00,010,0CANBus CANopen (DS402)Open loop o Closed loop
SW4A3070C261-00c0300  18560,07,10,010,0CANBus CANopen (DS301)Open loop o Closed loop
SW4A3070C261-02c0300  18560,07,10,010,0CANBus CANopen (DS301)Open loop o Closed loop con encoder assoluto
SW4A3070C261-00c0380  18560,07,10,010,0CANBus CANopen (DS402)Open loop o Closed loop
SW4A3070C261-01c0380  18560,07,10,010,0CANBus CANopen (DS402)Open loop o Closed loop
SW4A3070C261-02c0380  18560,07,10,010,0CANBus CANopen (DS402)Open loop o Closed loop con encoder assoluto
SW4A3070M261-00c0400  18560,07,10,010,0Seriale RS485 Modbus-RTUOpen loop o Closed loop
SW4A3070M261-01c0400  18560,07,10,010,0Seriale RS485 Modbus-RTUOpen loop o Closed loop
SW4A3070M261-02c0400  18560,07,10,010,0Seriale RS485 Modbus-RTUOpen loop o Closed loop con encoder assoluto
SW4A3070H241-00c0680  18560,07,10,010,0EtherCAT CoE (DS402)Open loop o Closed loop
SW4A3070H241-02c0680  18560,07,10,010,0EtherCAT CoE (DS402)Open loop o Closed loop con encoder assoluto
SW4A3070E241-00c0800  18560,07,10,010,0Ethernet Modbus TCP/IPOpen loop o Closed loop
SW4A3070E241-02c0800  18560,07,10,010,0Ethernet Modbus TCP/IPOpen loop o Closed loop con encoder assoluto
SW5A4085C2N1-00c0380  181000,08,50,012,0CANBus CANopen (DS402)Open loop o Closed loop
SW5A4085C2G1-00c0380  181000,08,50,012,0CANBus CANopen (DS402)Open loop o Closed loop
SW5A4085M2N1-00c0490  181000,08,50,012,0Modbus RTUOpen loop o Closed loop
SW5A4085M2G1-00c0490  181000,08,50,012,0Modbus RTUOpen loop o Closed loop
SW5A4085E241-00c0800  181000,08,50,012,0Ethernet Modbus TCP/IPOpen loop o Closed loop
SW5A4085E2J1-00c0800  181000,08,50,012,0Ethernet Modbus TCP/IPOpen loop o Closed loop
SW5A4085H241-00c0680  181000,08,50,012,0EtherCAT (CoE)Open loop o Closed loop
SW5A4085T2N1-00c0990  181000,08,50,012,0ProfinetOpen loop o Closed loop
SW5A9052L221-30c0380  852650,05,20,07,35CANBus CANopen (DS402) + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052L221-30c0700  852650,05,20,07,35CANBus CANopen (DS402) + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052L2E1-30c0380  852650,05,20,07,35CANBus CANopen (DS402) + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052L2E1-30c0700  852650,05,20,07,35CANBus CANopen (DS402) + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052L2G1-30c0380  852650,05,20,07,35CANBus CANopen (DS402) + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052L2G1-30c0700  852650,05,20,07,35CANBus CANopen (DS402) + Seriale ModbusOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052E221-30c0800  852650,05,20,07,35Ethernet Modbus TCP/IPOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052E2G1-30c0800  852650,05,20,07,35Ethernet Modbus TCP/IPOpen loop o Closed loop con encoder assoluto oppure incrementale
SW5A9052H221-30c0680  852650,05,20,07,35EtherCAT CoE (DS402)Open loop o Closed loop con encoder assoluto oppure incrementale